Skip to content
4-LOTJ-Industries-Buildings-Dark

The VFD Exchange is a team of traders with expertise in areas of manufacturing, supply chain management and the distribution of variable frequency drives (VFDs). Other common names for VFDs include variable speed drive (VSD), adjustable speed drive (ASD), variable voltage/variable frequency drive (VVVF), AC drive, and inverter drive. Our catalog only includes brand-new, never used VFDs for industrial manufacturing, HVAC, pumping, conveyors, agriculture, marine and more. Our mission is to be a reliable supply of quality VFDs for our customers at a competitive price. We have established relationships with vendors around the world so we can be a consistent source of high grade VFDs.

The VFD Exchange is a team of traders with expertise in areas of manufacturing, supply chain management and the distribution of variable frequency drives (VFDs). Other common names for VFDs include variable speed drive (VSD), adjustable speed drive (ASD), variable voltage/variable frequency drive (VVVF), AC drive, and inverter drive. Our catalog only includes brand-new, never used VFDs for industrial manufacturing, HVAC, pumping, conveyors, agriculture, marine and more. Our mission is to be a reliable supply of quality VFDs for our customers at a competitive price. We have established relationships with vendors around the world so we can be a consistent source of high grade VFDs.

Variable Frequency Drive (VFD) Catalog 2025

Variable Frequency Drive (VFD) Catalog 2025

[SUPPLY] Input: (1Ø) Single-Phase, 110V-115V

[MOTOR] Output (3Ø) Three-Phase, 200V-240V

(Variable Frequency Drives wit Voltage Doubler + Phase Conversion Capabilities)

 Horsepower   Amps  Enclosure Rating
0.5 HP (0.37kW) 2.3 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"
1.0 HP (0.75kW) 4.3 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"
1.5 HP (1.1kW) 5.8 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"

 

[SUPPLY] Input: (1Ø) Single-Phase, 200V-240V

[MOTOR] Output: (3Ø) Three-Phase, 200V-240V

(Variable Frequency Drives with Phase Conversion Capabilities)

 Horsepower   Amps  Enclosure Rating
0.5 HP (0.37kW) 2.3 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"
1.0 HP (0.75kW) 4.3 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"
2.0 HP (1.5kW) 7.0 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"
3.0 HP (2.2kW) 10.5 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"
5.0 HP (4.0kW) 15.3 A IP20 NEMA 1 NEMA 4X NEMA 4X "switched"

 

[SUPPLY] Input: (3Ø) Three-Phase, 200V-240V

[MOTOR] Output: (3Ø) Three-Phase, 200V-240V

 Horsepower   Amps  Enclosure Rating
0.5 HP (0.37kW) 2.3 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
1.0 HP (0.75kW) 4.3 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
2.0 HP (1.5kW) 7.0 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
3.0 HP (2.2kW) 10.5 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
5.0 HP (4.0kW) 18 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
7.5 HP (5.5kW) 24 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
10.0 HP  (7.5kW) 30 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
15 HP (11.0kW) 46 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
20 HP (15.0kW) 61 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
25 HP (18.5kW) 72 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
30 HP (22.0kW) 90 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
40 HP (30.0kW) 110 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
50 HP (37.0kW) 150 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
60 HP (45.0kW) 180 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
75 HP (55.0kW) 202 A IP20 NEMA 1 Bypass NEMA 12 NEMA 4X
100 HP (75kW) 248 A IP20 NEMA 1 Bypass NEMA 12 NEMA 4X

.

[SUPPLY] Input: (3Ø) Three-Phase, 380V-480V

[MOTOR] Output: (3Ø) Three-Phase, 380V-480V

 Horsepower   Amps  Enclosure Rating
1.0 HP (0.75kW) 2.2 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
2.0 HP (1.5kW) 4.1 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
3.0 HP (2.2kW) 5.8 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
5.0 HP (4.0kW) 9.5 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
7.5 HP (5.5kW) 14 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
10.0 HP (7.5kW) 18 A IP20 NEMA 1 Bypass NEMA 4X NEMA 4X "switched"
15 HP (11.0kW) 24 A IP20 NEMA 12 NEMA 4X NEMA 4X "switched"
20 HP (15.0kW) 30 A IP20 NEMA 12 NEMA 4X NEMA 4X "switched"
25 HP (18.5kW) 39 A IP20 NEMA 12 NEMA 4X NEMA 4X "switched"
30 HP (22.0kW) 46 A IP20 NEMA 12 NEMA 4X NEMA 4X "switched"
40 HP (30.0kW) 61 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
50 HP (37.0kW) 72 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
60 HP (45.0kW) 90 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
75 HP (55.0kW) 110 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
100 HP (75.0kW) 150 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
150 HP (90.0kW) 180 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
175 HP (110kW) 202 A IP20 NEMA 1 Bypass NEMA 12 NEMA 3R Bypass
200 HP (132kW) 240 A IP20 NEMA 1 Bypass NEMA 12 NEMA 4X
250 HP (160kW) 302 A IP20 NEMA 1 Bypass NEMA 12 NEMA 4X
300 HP (200kW) 370 A IP20 NEMA 1 Bypass NEMA 12 NEMA 4X
400 HP (250kW) 480 A IP20 NEMA 1 Bypass NEMA 12 NEMA 4X

Available VFD Enclosure Ratings

IP20

Enclosures constructed for panel mounting with some ingress protection against dust. Protected against solid foreign objects of 12.5mm 𝜙 and greater. No protection against water or liquids. Do not wall mount, should be properly mounted inside additional enclosure with NEMA rating that meets specification requirement.

NEMA 1

Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt).

NEMA 12

Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).

NEMA 3R

Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.

NEMA 4X

Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.