Description
Variable Frequency Drive for Fan & Pump Applications
– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors
HVAC BUILDING SERVICES
– Maximum Fan Efficiency
– Accurate speed control of fans and pumps provides the most energy efficient control method
– Energy optimization function minimizes energy usage in real time under partial load conditions
– Sleep & wake functions ensure operation only when required
– Advanced on-board features remove the need for peripheral equipment
– Intelligent maintenance interval timing allows programmable maintenance reminders, avoiding costly downtime
– Automatic load monitoring provides an early warning of potential faults, such as belt failures or blocked filters
– Building Safety Systems: Stairwell Pressurization, Fume Extraction, Fire Override
– Fire override: Mode ignores signals and alarms, keeping the drive operating for as long as possible
– Energy Efficient Air Handling: Can vary the output of air conditioning system to meet the varying demands throughout the day, maximum occupancy and peak outside ambient
– Belt Break Detection: Provide immediate warning of broken belt between motor and fan
PUMP CONTROL
– Maximum Pumping Efficiency
– OPTIFLOW technology allows simple operation of multiple pump sets without the need for a PLC
– Pump blockage detection and cleaning dramatically reduces pump maintenance requirements
– Built-in PLC function
– Dry Run Protection: Drive can evaluate pump’s speed/power and shut it off or warn when the pump starts to run dry
– Motor Preheat Function: insures moisture does not collect on the motor in periods of inactivity and prior to motor start up
– Pump Stir Cycle: Triggered by a settable period of inactivity, a configurable cleaning cycle can be run to clear sediment
– Consistent Flow: Pump operating curve detection automatically detects and monitors normal pump behavior and is able to react when pumping conditions change
– Pump Prime with Burst Pipe Detection: helps to prevent the effects of water hammering
– Advanced sleep & wake functions provide maximum energy savings by switching off the pump when not required
– Any pump can be switched to Hand operation a the touch of a button, and will automatically rejoin the network when switched back to Auto
– For waste water applications, each pump can be set for blockage/ragging detection and activate an automatic de-ragging/pump cleaning cycle
Compatible motors
– Induction Motors (IM)
– Permanent Magnet Motors (PM)
– Brushless DC Motors (BLDC)
– Synchronous Reluctance Motors (SynRM)
Standards Compliance
– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 & NEMA 4X Drives: 3S3/3C3
I/O Specifications
– Power Supply: 24 Volt DC, 100mA, Short Circuit Protected. 10 Volt DC, 10mA for Potentiometer
– Programmable Inputs: 5 Total as standard (Optional additional 3), 3 Digital (Optional additional 3), 2 Analog / Digital Selectable
– Digital Inputs: Opto – Isolated, 8 – 30 Volt DC, internal or external supply Response time < 4ms
– Analog Inputs: Resolution : 12 bits, Response time : < 4ms, Accuracy : <1% full scale
– Parameter adjustable scaling and offset
– Programmable Outputs: 2 Total, 1 Analog / Digital, 1 Relay
– Relay Outputs: Maximum Voltage 250 VAC, 30 VDC. Switching Current Capacity 5A
– Analog Outputs: 0 to 10 Volts / 10 to 0 Volts, 0 to 20mA / 20 to 0mA, 4 to 20mA / 20 to 4mA
– Plug-in Options: Extended I/O (Additional 3 Digital Inputs, Additional Relay Output). Cascade Control: Additional 3 Relay Outputs
Input Ratings (Supply Voltage)
– 200 – 240 Volts ± 10%
– 380 – 480 Volts ± 10%
– 500 – 600 Volts ± 10%
– Supply Frequency: 48 – 62 Hz
Output Power
– 230 Volt 1 Phase Input : Up to 10.5 A / 3 HP
– 230 Volt 3 Phase Input : Up to 248 A / 100 HP
– 400 Volt 3 Phase Input : Up to 450 A / 350 HP
– 460 Volt 3 Phase Input : Up to 450 A / 350 HP
– 575 Volt 3 Phase Input : Up to 150 A / 150 HP
– Output Frequency: 0 – 500 Hz, 0.1 Hz resolution
– Overload Capacity: 110% for 60 seconds, 165% for 4 seconds
– Acceleration Time: 0.01 – 600 seconds
– Deceleration Time: 0.01 – 600 seconds
– PWM (Switching) Frequency: 4 – 32kHz Effective
Ambient Conditions
– Storage Temperature: -40 to 60°C
– Operating Temperature: -10 to 50°C
– Humidity: 95% Max, non condensing
– Vibration: Conforms to EN61800-5-1 2007, IEC 60068-2-6
Programming
– Keypad: Built-in Keypad as standard. Optional remote mountable keypad
– Display: Built-in Multi-Language TFT display (IP20 & NEMA 4X), TFT & OLED (NEMA 12)
– PC: OptiTools Studio
Control Method
– Eco Sensorless Vector
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
Setpoint Control
– Analog Signals:
– 0 to 10 Volts, 10 to 0 Volts, -10 to + 10 Volts, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA
– Digital: Motorized Potentiometer (Keypad), Modbus RTU, BACnet MS/TP
Fieldbus Connectivity
– Built-in: BACnet MS/TP: BACnet Application Specific Controller 9.6 – 76.8 kbps selectable Data Format: 8N1, 8N2, 8O1, 8E1. Modbus RTU: 9.6 – 115.2 kbps selectable 8N1, 8N2, 8E1, 8O1
– Optional: BACnet/IP: Plug-in BACnet/IP interface, Dual LAN ports, Device Level Ring. Other: PROFIBUS DP (DPV1), PROFINET IO, DeviceNet, EtherNet/IP, EtherCat, Modbus TCP
Application Features
– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant
Pump Control Features
– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up
Maintenance & Diagnostics
– Fault Memory: Last 4 Trips stored with time stamp
– Data Logging: Logging of data prior to trip for diagnostic purposes (Output Current, Drive Temperature, DC Bus Voltage)
– Maintenance Indicator: Maintenance Indicator with user adjustable maintenance interval, Onboard service life monitoring
– Monitoring: Hours Run Meter, Resettable & Non-Resettable kWh meters, Cooling Fan Run Time
Hand / Auto
– Allows manual control to easily be selected, Fast temporary override
Drive Controlled Bypass
– Can operate as a bypass controller when installed as part of a bypass circuit
– Activation of Bypass mode can be determined intelligently by the drive