ODV-3-320240-3F1E-MN – 7.5HP, 24A, 200V – 240V, Three Phase

$ 1,793.28

Model ID: ODV-3-320240-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

Horsepower: 7.5 HP

Input Voltage: 200V – 240V
Output Voltage: 200V – 240V
Phase: 3Ø
Output Current: 24A
Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

Request a Quote

Description

VFD 7.5HP, 200V-240V, 3Ø

Model ID: ODV-3-320240-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control

– Open Loop Permanent Magnet Vector

– Open Loop BLDC Vector

– Open Loop Synchronous Reluctance Vector

– BACnet and Modbus RTU onboard as standard

– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency

– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

HVAC BUILDING SERVICES

– Maximum Fan Efficiency

– Accurate speed control of fans and pumps provides the most energy efficient control method

– Energy optimization function minimizes energy usage in real time under partial load conditions

– Sleep & wake functions ensure operation only when required

– Advanced on-board features remove the need for peripheral equipment

– Intelligent maintenance interval timing allows programmable maintenance reminders, avoiding costly downtime

– Automatic load monitoring provides an early warning of potential faults, such as belt failures or blocked filters

– Building Safety Systems: Stairwell Pressurization, Fume Extraction, Fire Override

– Fire override: Mode ignores signals and alarms, keeping the drive operating for as long as possible

– Energy Efficient Air Handling: Can vary the output of air conditioning system to meet the varying demands throughout the day, maximum occupancy and peak outside ambient

– Belt Break Detection: Provide immediate warning of broken belt between motor and fan

PUMP CONTROL

– Maximum Pumping Efficiency

– OPTIFLOW technology allows simple operation of multiple pump sets without the need for a PLC

– Pump blockage detection and cleaning dramatically reduces pump maintenance requirements

– Built-in PLC function

– Dry Run Protection: Drive can evaluate pump’s speed/power and shut it off or warn when the pump starts to run dry

– Motor Preheat Function: insures moisture does not collect on the motor in periods of inactivity and prior to motor start up

– Pump Stir Cycle: Triggered by a settable period of inactivity, a configurable cleaning cycle can be run to clear sediment

– Consistent Flow: Pump operating curve detection automatically detects and monitors normal pump behavior and is able to react when pumping conditions change

– Pump Prime with Burst Pipe Detection: helps to prevent the effects of water hammering

– Advanced sleep & wake functions provide maximum energy savings by switching off the pump when not required

– Any pump can be switched to Hand operation a the touch of a button, and will automatically rejoin the network when switched back to Auto

– For waste water applications, each pump can be set for blockage/ragging detection and activate an automatic de-ragging/pump cleaning cycle

Compatible Motors

– Induction Motors (IM)

– Permanent Magnet Motors (PM)

– Brushless DC Motors (BLDC)

– Synchronous Reluctance Motors (SynRM)

Standards Compliance

– Low Voltage Directive: 2014/35/EU

– EMC Directive: 2014/30/EU

– Additional Conformance: UL, cUL, EAC, RCM

– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

I/O Specifications

– Power Supply: 24 Volt DC, 100mA, Short Circuit Protected. 10 Volt DC, 10mA for Potentiometer

– Programmable Inputs: 5 Total as standard (Optional additional 3), 3 Digital (Optional additional 3), 2

Analog / Digital Selectable

– Digital Inputs: Opto – Isolated, 8 – 30 Volt DC, internal or external supply Response time less than 4ms

– Analog Inputs: Resolution 12 bits, Response time less than 4ms, Accuracy less than 1% full scale

– Parameter adjustable scaling and offset

– Programmable Outputs: 2 Total, 1 Analog / Digital, 1 Relay

– Relay Outputs: Maximum Voltage 250 VAC, 30 VDC. Switching Current Capacity 5A

– Analog Outputs: 0 to 10 Volts / 10 to 0 Volts, 0 to 20mA / 20 to 0mA, 4 to 20mA / 20 to 4mA

– Plug-in Options: Extended I/O (Additional 3 Digital Inputs, Additional Relay Output). Cascade Control: Additional 3 Relay Outputs

Output Power

– 230 Volt 1 Phase Input : Up to 30 A / 10 HP

– 230 Volt 3 Phase Input : Up to 248 A / 100 HP

– 400 Volt 3 Phase Input : Up to 450 A / 400 HP

– 460 Volt 3 Phase Input : Up to 450 A / 400 HP

– 575 Volt 3 Phase Input : Up to 150 A / 150 HP

– Output Frequency: 0 – 500 Hz, 0.1 Hz resolution

– Overload Capacity: 110% for 60 seconds, 165% for 4 seconds

– Acceleration Time: 0.01 – 600 seconds

– Deceleration Time: 0.01 – 600 seconds

– PWM (Switching) Frequency: 4 – 32kHz Effective

Ambient Conditions

– Storage Temperature: -40 to 60°C

– Operating Temperature: -10 to 50°C

– Humidity: 95% Max, non condensing

– Vibration: Conforms to EN61800-5-1 2007, IEC 60068-2-6

Control Method

– Eco Sensorless Vector

– Open Loop Permanent Magnet Vector

– Open Loop BLDC Vector

– Open Loop Synchronous Reluctance Vector

Setpoint Control

– Analog Signals: 0 to 10 Volts, 10 to 0 Volts, -10 to + 10 Volts, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA

– Digital: Motorized Potentiometer (Keypad), Modbus RTU, BACnet MS/TP

Fieldbus Connectivity

– Built-in: BACnet MS/TP: BACnet Application Specific Controller 9.6 – 76.8 kbps selectable Data Format: 8N1, 8N2, 8O1, 8E1. Modbus RTU: 9.6 – 115.2 kbps selectable 8N1, 8N2, 8E1, 8O1

– Optional: BACnet/IP: Plug-in BACnet/IP interface, Dual LAN ports, Device Level Ring. Other: PROFIBUS DP (DPV1), PROFINET IO, DeviceNet, EtherNet/IP, EtherCat, Modbus TCP

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function

– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)

– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning

– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable

– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation

– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network

– Pump Stir: Automatic pump stir to prevent sediment build-up

Maintenance and Diagnostics

– Fault Memory: Last 4 Trips stored with time stamp

– Data Logging: Logging of data prior to trip for diagnostic purposes (Output Current, Drive Temperature, DC Bus Voltage)

– Maintenance Indicator: Maintenance Indicator with user adjustable maintenance interval, Onboard service life monitoring

– Monitoring: Hours Run Meter, Resettable & Non-Resettable kWh meters, Cooling Fan Run Time

Drive Controlled Bypass – Hand/Auto

– Can operate as a bypass controller when installed as part of a bypass circuit with manual control override and internal VFD activation for Direct On Line (DOL)

Additional information

Weight 15 lbs
Datasheet

ODV-3-320240-3F1E-MN

User Guide

Optidrive ECO

Replaces

ODV-3-320240-3F1D-TN ("TN" included OLED display. "MN" includes TFT display). Previous model was "Indoor Rated" NEMA 4X. New model is "Outdoor Rated" NEMA 4X.