OUTPUT (MOTOR VOLTAGE): 200V-240V – Variable Frequency Drives – VFDs – The VFD Exchange https://vfdexchange.com An exclusive variable frequency drive marketplace! Sat, 20 Sep 2025 22:09:17 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.2 https://vfdexchange.com/wp-content/uploads/2020/11/cropped-vfd.com_logo_10000res-32x32.webp OUTPUT (MOTOR VOLTAGE): 200V-240V – Variable Frequency Drives – VFDs – The VFD Exchange https://vfdexchange.com 32 32 BC32030-00CSFT-0HEX0-F01 – 30HP, 90A, 200V – 240V, Three Phase https://vfdexchange.com/product/bc32030-00csft-0hex0-f01-30hp-90a-200v-240v-three-phase Tue, 17 Jun 2025 02:55:14 +0000 https://vfdexchange.com/?post_type=product&p=13004 Model ID: BC32030-00CSFT-0HEX0-F01 Series: Optipass (VFD with Bypass) Manufacturer: Invertek Drives

Horsepower: 30 HP

Input Voltage: 200V – 240V Output Voltage: 200V – 240V Phase: 3Ø Output Current: 90.0A Enclosure Rating: NEMA 1, Bypass Contactor Type: 3 Contactor Disconnect: Circuit Breaker, Rotary Type

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD Bypass BC32030-00CSFT-0HEX0-F01

– Enclosure Rating: NEMA 1, Bypass
– Frame: Size 3
– Contactor Type: 3 Contactor
– Disconnect Type: Circuit Breaker, Rotary Type
– Fieldbus: BACnet MS/TP, Modbus RTU

Build To Order 3 weeks lead time

– 2 weeks lead time to build panel assembly
– Additional 1 week with LTL freight shipping
– Contact for expedited shipping quotation

Specifications

– SCCR: 50KAIC
– VFD Protection: Fused 100A Type CC
– Drive Line Side Service Disconnect: No
– Surge Suppressor: No
– Overload: Motor Thermal Overload
– Operators: Keypad, VFD-Off-Bypass, RJ45
– Indicators: Bypass ON / Overload LED
– Ventilation: Fan w/ Thermostat (NEMA1)
– Wired+Assembled: ETL/UL/CSA 508C
– Panel Dimensions: 60.0” x 36.0” x 16.8”
– Weight: 446 lbs

Optipass Brochure User Manual

Variable Frequency Drive with Bypass

– Standard panel assembly with Model ID # ODV-3-520900-3F12-MN
* Upon request, a bypass panel assembly can be configured with the Invertek Drives Optidrive P2 High Performance Series hardware, loaded with Optidrive ECO firmware. This configuration is best suited for heavy-duty and high-torque applications.

]]>
BC32030-00CSFT-0HEX0-B3R – 30HP, 90A, 200V – 240V, Three Phase https://vfdexchange.com/product/bc32030-00csft-0hex0-b3r Tue, 03 Sep 2024 00:21:46 +0000 https://vfdexchange.com/?post_type=product&p=11458 Model ID: BC32030-00CSFT-0HEX0-B3R Series: Optipass (VFD with Bypass) Manufacturer: Invertek Drives

Horsepower: 30 HP

Input Voltage: 200V – 240V Output Voltage: 200V – 240V Phase: 3Ø Output Current: 90.0A Enclosure Rating: NEMA 3R, Bypass Contactor Type: 3 Contactor Disconnect: Circuit Breaker, Rotary Type

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD Bypass BC32030-00CSFT-0HEX0-B3R

– Enclosure Rating: NEMA 3R, Bypass
– Frame: Size 5
– Contactor Type: 3 Contactor
– Disconnect Type: Circuit Breaker, Rotary Type
– Fieldbus: BACnet MS/TP, Modbus RTU

Build To Order 3 weeks lead time

– 2 weeks lead time to build panel assembly
– Additional 1 week with LTL freight shipping
– Contact for expedited shipping quotation

Specifications

– SCCR: 50KAIC
– VFD Protection: Fused 100A Type CC
– Drive Line Side Service Disconnect: No
– Surge Suppressor: No
– Overload: Motor Thermal Overload
– Operators: Keypad, VFD-Off-Bypass, RJ45
– Indicators: Bypass ON / Overload LED
– Ventilation: Filter Fan and Heater w/ Dual Thermostat (NEMA3R)
– Wired+Assembled: ETL/UL/CSA 508C
– Panel Dimensions: 72.0″ x 36.0″ x 16.8″
– Weight: 543 lbs

Optipass Brochure User Manual

Variable Frequency Drive with Bypass

– Standard panel assembly with Model ID # ODV-3-520900-3F12-MN
* Upon request, a bypass panel assembly can be configured with the Invertek Drives Optidrive P2 High Performance Series hardware, loaded with Optidrive ECO firmware. This configuration is best suited for heavy-duty and high-torque applications.

]]>
BC22030-00CSFT-0HEX0-B3R – 30HP, 90A, 200V – 240V, Three Phase https://vfdexchange.com/product/bc22030-00csft-0hex0-b3r Mon, 02 Sep 2024 03:20:19 +0000 https://vfdexchange.com/?post_type=product&p=11426 Model ID: BC22030-00CSFT-0HEX0-B3R Series: Optipass (VFD with Bypass) Manufacturer: Invertek Drives

Horsepower: 30 HP

Input Voltage: 200V – 240V Output Voltage: 200V – 240V Phase: 3Ø Output Current: 90.0A Enclosure Rating: NEMA 3R, Bypass Contactor Type: 2 Contactor Disconnect: Circuit Breaker, Rotary Type

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD Bypass BC22030-00CSFT-0HEX0-B3R

– Enclosure Rating: NEMA 3R, Bypass
– Frame: Size 5
– Contactor Type: 2 Contactor
– Disconnect Type: Circuit Breaker, Rotary Type
– Fieldbus: BACnet MS/TP, Modbus RTU

Build To Order 3 weeks lead time

– 2 weeks lead time to build panel assembly
– Additional 1 week with LTL freight shipping
– Contact for expedited shipping quotation

Specifications

– SCCR: 50KAIC
– VFD Protection: Fused 100A Type CC
– Drive Line Side Service Disconnect: No
– Surge Suppressor: No
– Overload: Motor Starter, Type E
– Operators: Keypad, VFD-Off-Bypass, RJ45
– Indicators: Bypass ON / Overload LED
– Ventilation: Filter Fan and Heater w/ Dual Thermostat (NEMA3R)
– Wired+Assembled: ETL/UL/CSA 508C
– Panel Dimensions: 72.0” x 36.0” x 16.8”
– Weight: 543 lbs

Optipass Brochure User Manual

Variable Frequency Drive with Bypass

– Standard panel assembly with Model ID # ODV-3-520900-3F12-MN
* Upon request, a bypass panel assembly can be configured with the Invertek Drives Optidrive P2 High Performance Series hardware, loaded with Optidrive ECO firmware. This configuration is best suited for heavy-duty and high-torque applications.

]]>
BC22030-00CSFT-0HEX0-F01 – 30HP, 90A, 200V – 240V, Three Phase https://vfdexchange.com/product/bc22030-00csft-0hex0-f01 Fri, 30 Aug 2024 19:11:26 +0000 https://vfdexchange.com/?post_type=product&p=11374 Model ID: BC22030-00CSFT-0HEX0-F01 Series: Optipass (VFD with Bypass) Manufacturer: Invertek Drives

Horsepower: 30 HP

Input Voltage: 200V – 240V Output Voltage: 200V – 240V Phase: 3Ø Output Current: 90.0A Enclosure Rating: NEMA 1, Bypass Contactor Type: 2 Contactor Disconnect: Circuit Breaker, Rotary Type

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD Bypass BC22030-00CSFT-0HEX0-F01

– Enclosure Rating: NEMA 1, Bypass
– Frame: Size 3
– Contactor Type: 2 Contactor
– Disconnect Type: Circuit Breaker, Rotary Type
– Fieldbus: BACnet MS/TP, Modbus RTU

Build To Order 3 weeks lead time

– 2 weeks lead time to build panel assembly
– Additional 1 week with LTL freight shipping
– Contact for expedited shipping quotation

Specifications

– SCCR: 50KAIC
– VFD Protection: Fused 100A Type CC
– Drive Line Side Service Disconnect: No
– Surge Suppressor: No
– Overload: Motor Thermal Overload
– Operators: Keypad, VFD-Off-Bypass, RJ45
– Indicators: Bypass ON / Overload LED
– Ventilation: Fan w/ Thermostat (NEMA1)
– Wired+Assembled: ETL/UL/CSA 508C
– Panel Dimensions: 60.0” x 36.0” x 16.8”
– Weight: 446 lbs

Optipass Brochure User Manual

Variable Frequency Drive with Bypass

– Standard panel assembly with Model ID # ODV-3-520900-3F12-MN
* Upon request, a bypass panel assembly can be configured with the Invertek Drives Optidrive P2 High Performance Series hardware, loaded with Optidrive ECO firmware. This configuration is best suited for heavy-duty and high-torque applications.

]]>