Invertek Drives – Optidrive ECO – Pump & Fan – NEMA 4X “Switched” – Variable Frequency Drives – VFDs – The VFD Exchange https://vfdexchange.com An exclusive variable frequency drive marketplace! Sat, 18 Oct 2025 02:00:55 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.3 https://vfdexchange.com/wp-content/uploads/2020/11/cropped-vfd.com_logo_10000res-32x32.webp Invertek Drives – Optidrive ECO – Pump & Fan – NEMA 4X “Switched” – Variable Frequency Drives – VFDs – The VFD Exchange https://vfdexchange.com 32 32 ODV-3-420300-101E-MN – 10HP, 30A, 200V – 240V, Single Phase https://vfdexchange.com/product/odv-3-420300-101e-mn Thu, 31 Aug 2023 03:52:52 +0000 https://vfdexchange.com/?post_type=product&p=10634 Model ID: ODV-3-420300-101E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 10 HP

Input Voltage: 200V – 240V Output Voltage: 200V – 240V Phase I/O: 1Ø / 3Ø Output Current: 30A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 10HP, 200V-240V, 1Ø/3Ø

Model ID: ODV-3-420300-101E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-420240-101E-MN – 7.5HP, 24A, 200V – 240V, Single Phase https://vfdexchange.com/product/odv-3-420240-101e-mn Thu, 31 Aug 2023 03:19:50 +0000 https://vfdexchange.com/?post_type=product&p=10629 Model ID: ODV-3-420240-101E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 7.5 HP

Input Voltage: 200V – 240V Output Voltage: 200V – 240V Phase I/O: 1Ø / 3Ø Output Current: 24A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 7.5HP, 200V-240V, 1Ø/3Ø

Model ID: ODV-3-420240-101E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-320153-1F1E-MN – 5HP, 15.3A, 200V – 240V, Single Phase https://vfdexchange.com/product/odv-3-320153-1f1e-mn Thu, 31 Aug 2023 02:48:29 +0000 https://vfdexchange.com/?post_type=product&p=10625 Model ID: ODV-3-320153-1F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 5 HP

Input Voltage: 200V – 240V Output Voltage: 200V – 240V Phase I/O: 1Ø / 3Ø Output Current: 15.3A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 5HP, 200V-240V, 1Ø/3Ø

Model ID: ODV-3-320153-1F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-440460-3F1E-MN – 30HP, 46A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-440460-3f1e-mn Fri, 09 Apr 2021 02:32:03 +0000 https://vfdexchange.com/?post_type=product&p=8365 Model ID: ODV-3-440460-3F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 30 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 46A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 30HP, 380V-480V, 3Ø

Model ID: ODV-3-340460-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-440390-3F1E-MN – 25HP, 39A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-440390-3f1e-mn Fri, 09 Apr 2021 02:25:00 +0000 https://vfdexchange.com/?post_type=product&p=8363 Model ID: ODV-3-440390-3F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 25 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 39A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 25HP, 380V-480V, 3Ø

Model ID: ODV-3-440390-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-340300-3F1E-MN – 20HP, 30A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-340300-3f1e-mn Fri, 09 Apr 2021 02:18:19 +0000 https://vfdexchange.com/?post_type=product&p=8358 Model ID: ODV-3-340300-3F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 20 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 30A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 20HP, 380V-480V, 3Ø

Model ID: ODV-3-340300-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-340240-3F1E-MN – 15HP, 24A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-340240-3f1e-mn Fri, 09 Apr 2021 02:05:46 +0000 https://vfdexchange.com/?post_type=product&p=8356 Model ID: ODV-3-340240-3F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 15 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 24A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 15HP, 380V-480V, 3Ø

Model ID: ODV-3-340240-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-340180-3F1E-MN – 10HP, 18A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-340180-3f1e-mn Fri, 09 Apr 2021 01:55:22 +0000 https://vfdexchange.com/?post_type=product&p=8354 Model ID: ODV-3-340180-3F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 10 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 18A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 10HP, 380V-480V, 3Ø

Model ID: ODV-3-340180-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-240095-3F1E-MN – 5HP, 9.5A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-240095-3f1e-mn Fri, 09 Apr 2021 01:39:12 +0000 https://vfdexchange.com/?post_type=product&p=8351 Model ID: ODV-3-240095-3F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 5 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 9.5A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 5HP, 380V-480V, 3Ø

Model ID: ODV-3-240095-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-240140-3F1E-MN – 7.5HP, 14A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-240140-3f1e-mn Fri, 09 Apr 2021 01:28:17 +0000 https://vfdexchange.com/?post_type=product&p=8349 Model ID: ODV-3-240140-3F1E-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 7.5 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 14A Enclosure Rating: NEMA 4X / IP66

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 7.5HP, 380V-480V, 3Ø

Model ID: ODV-3-240140-3F1E-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>