Invertek Drives – Optidrive ECO – Pump & Fan – IP20 – Variable Frequency Drives – VFDs – The VFD Exchange https://vfdexchange.com An exclusive variable frequency drive marketplace! Sat, 06 Dec 2025 02:04:31 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.1 https://vfdexchange.com/wp-content/uploads/2020/11/cropped-vfd.com_logo_10000res-32x32.webp Invertek Drives – Optidrive ECO – Pump & Fan – IP20 – Variable Frequency Drives – VFDs – The VFD Exchange https://vfdexchange.com 32 32 ODV-3-844800-3R12-MN – 400HP, 480A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-844800-3r12-mn Sat, 10 Aug 2024 02:55:00 +0000 https://vfdexchange.com/?post_type=product&p=11307 Model ID: ODV-3-844800-3R12-MN Series: Optidrive ECO EMC Filter: High Performance Cat C2 Manufacturer: Invertek Drives

Horsepower: 400 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 480A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id=“205"]]]>
VFD 400HP, 380V-480V, 3Ø

Model ID: ODV-3-844800-3R12-MN
Series: Optidrive ECO
EMC Filter: High Performance Cat C2
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-843700-3R12-MN – High Performance EMC Filter – 300HP, 370A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-843700-3r12-mn Sat, 10 Aug 2024 02:38:18 +0000 https://vfdexchange.com/?post_type=product&p=11304 Model ID: ODV-3-843700-3R12-MN Series: Optidrive ECO EMC Filter: High Performance Cat C2 Manufacturer: Invertek Drives

Horsepower: 300 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 370A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id=“205"]]]>
VFD 300HP, 380V-480V, 3Ø

Model ID: ODV-3-843700-3R12-MN
Series: Optidrive ECO
EMC Filter: High Performance Cat C2
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-844800-3F12-MN – 400HP, 480A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-844800-3f12-mn Fri, 18 Aug 2023 19:14:47 +0000 https://vfdexchange.com/?post_type=product&p=10185 Model ID: ODV-3-844800-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 400 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 480A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 400HP, 380V-480V, 3Ø

Model ID: ODV-3-844800-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-843700-3F12-MN – 300HP, 370A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-843700-3f12-mn Fri, 18 Aug 2023 19:05:29 +0000 https://vfdexchange.com/?post_type=product&p=10179 Model ID: ODV-3-843700-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 300 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 370A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 300HP, 380V-480V, 3Ø

Model ID: ODV-3-843700-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-642020-3F12-MN – 175HP, 202A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-642020-3f12-mn Mon, 29 Mar 2021 22:00:13 +0000 https://vfdexchange.com/?post_type=product&p=8193 Model ID: ODV-3-642020-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 175 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 202A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 175HP, 380V-480V, 3Ø

Model ID: ODV-3-642020-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-641800-3F12-MN – 150HP, 180A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-641800-3f12-mn Mon, 29 Mar 2021 21:53:56 +0000 https://vfdexchange.com/?post_type=product&p=8191 Model ID: ODV-3-641800-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 150 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 180A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 150HP, 380V-480V, 3Ø

Model ID: ODV-3-641800-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-641500-3F12-MN – 100HP, 150A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-641500-3f12-mn Mon, 29 Mar 2021 21:48:05 +0000 https://vfdexchange.com/?post_type=product&p=8189 Model ID: ODV-3-641500-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 100 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 150A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 100HP, 380V-480V, 3Ø

Model ID: ODV-3-641500-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-641100-3F12-MN – 75HP, 110A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-641100-3f12-mn Mon, 29 Mar 2021 16:52:40 +0000 https://vfdexchange.com/?post_type=product&p=8187 Model ID: ODV-3-641100-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 75 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 110A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 75HP, 380V-480V, 3Ø

Model ID: ODV-3-641100-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-540900-3F12-MN – 60HP, 90A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-540900-3f12-mn Mon, 29 Mar 2021 16:42:40 +0000 https://vfdexchange.com/?post_type=product&p=8185 Model ID: ODV-3-540900-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 60 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 90A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 60HP, 380V-480V, 3Ø

Model ID: ODV-3-540900-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>
ODV-3-540720-3F12-MN – 50HP, 72A, 380V – 480V, Three Phase https://vfdexchange.com/product/odv-3-540720-3f12-mn Mon, 29 Mar 2021 16:29:22 +0000 https://vfdexchange.com/?post_type=product&p=8183 Model ID: ODV-3-540720-3F12-MN Series: Optidrive ECO Manufacturer: Invertek Drives

Horsepower: 50 HP

Input Voltage: 380V – 480V Output Voltage: 380V – 480V Phase: 3Ø Output Current: 72A Enclosure Rating: IP20

Call Today: 1-800-970-6340

[maxbutton id="205"]]]>
VFD 50HP, 380V-480V, 3Ø

Model ID: ODV-3-540720-3F12-MN
Series: Optidrive ECO
Manufacturer: Invertek Drives

User Manual

Variable Frequency Drive for Fan and Pump Applications

– Unique Eco Vector Sensorless Control
– Open Loop Permanent Magnet Vector
– Open Loop BLDC Vector
– Open Loop Synchronous Reluctance Vector
– BACnet and Modbus RTU onboard as standard
– Frame size 1-5 utilize film capacitor in the DC link, providing exceptionally low harmonic current distortion without compromising efficiency
– Frame size 6-8 include DC chokes and traditional electrolytic capacitors

Standards Compliance

– Low Voltage Directive: 2014/35/EU
– EMC Directive: 2014/30/EU
– Additional Conformance: UL, cUL, EAC, RCM
– Environmental Conditions: Designed to meet IEC 60721-3-3, in operation. IP20 Drives: 3S2/3C2. NEMA 12 and NEMA 4X Drives: 3S3/3C3

Application Features

– PID Control: Internal PID Controller, Multi-setpoint. Select Standby / Sleep Mode, Boost Function
– Fire Mode: Bidirectional, Selectable Speed Setpoint (Fixed / PID / Analog / Fieldbus)
– Load Monitoring: High Current Protection (Fan / Bump Blocked), Low Current Protection (Broken Belt / Shaft), Pump Blockage Detection with Cleaning
– Duty / Assist / Standby: Built-in Multi-Pump Support, Automatic Changeover on Fault, Automatic Changeover on Time, Fully Redundant

Pump Control Features

– Pump Blockage Detection: Pump load monitoring with autotune function, user configurable
– Pump Cleaning: Adjustable Bi-directional Pump Cleaning Cycle operation
– Multi-Pump Control: Control of fixed speed assist pumps (with cascade control module), Control of Duty, Assist and Standby variable speed pumps via internal Master – Slave network
– Pump Stir: Automatic pump stir to prevent sediment build-up

Click Here for Optidrive ECO Specifications

]]>